Latest Legacy

The Conference object

Attributes

conference_name string

The name used to identify the conference.

conference_run_time string

Time in seconds since the conference was initiated.

conference_member_count string

Number of members currently active in the conference.

Note: Along with the above attributes, the response includes the following attributes for each member active in the conference.
member_id string

The ID of the member in the conference. This ID is unique for each conference.

muted boolean

Set to true if the member is currently muted.

deaf boolean

Set to true if the member cannot hear the conversations taking place in the conference.

from string

The source from which the call was made to the conference. This can either be a PSTN number or a SIP endpoint.

to string

The conference bridge number. This can either be a Plivo number or an application URL.

caller_name string

The name of the caller, if the call was made from a SIP endpoint. This field is empty if no caller name is specified while making the call.

direction string

The direction of the call. This can either be inbound or outbound.

call_uuid string

The call_uuid that uniquely identifies the call.

join_time string

The time in seconds since the call joined the conference.

Response

{
  "conference_name": "My Conf Room",
  "conference_run_time": "590",
  "conference_member_count": "1",
  "members": [
{
  "muted" : false,
  "member_id" : "17",
  "deaf" : false,
  "from" : "1456789903",
  "to" : "1677889900",
  "caller_name" : "John",
  "direction" : "inbound",
  "call_uuid" : "acfbf0b5-12e0-4d74-85f7-fce15f8f07ec",
  "join_time" : "590"
}
  ]
}